A Teensy-based interface reads Rivian battery data without replacing the factory monitoring boards

Rivian, BMS, EV conversion

This is the read-only HTML version. For the full Visual Space experience, open the app.

Battery modules, electronics —

Battery modules, electronics —
Battery modules, electronics —
Battery modules, electronics —
Battery modules, electronics —
Battery modules, electronics —
Battery modules, electronics —
Battery modules, electronics —
Battery modules, electronics —

Credit: Lost-Bed-8458 r/EVConversion

Battery reuse, isoSPI

An LTC6820 bridge connects a microcontroller to Rivian’s existing battery-monitoring electronics. The builder reports access to cell voltages and temperatures, with an openVCU BMS in development for a nine-module EV conversion. Reading the data is a useful milestone—not yet proof of a complete protection system.

🔥 1

Reusing Rivian batteries in an EV conversion raises a practical question: can a new controller work with the monitoring electronics already attached to them? Reddit user Lost-Bed-8458 reports that it can, sharing bench tests in r/EVConversion on November 6, 2026. Their Teensy 4.1 setup accesses cell voltages and temperatures through the factory BVT boards, rather than replacing those boards to obtain the measurements.

The useful result is that the existing monitoring hardware can stay in place while the builder develops a new battery management system around it. That is a narrower—and more actionable—milestone than universal aftermarket BMS compatibility.

An LTC6820 bridges the communication gap

The component identification took some close inspection. According to the builder, Rivian’s board coating obscured the markings enough to require magnification and changes in lighting angle. They identified LTC6810G-1 chips, then ordered an Analog Devices LTC6820 demonstration board for bench testing.

The communication path is straightforward to describe: the microcontroller sends messages over SPI to the LTC6820, which translates them to isoSPI for the battery’s factory monitoring boards. The key distinction is between the new controller and the electronics doing the measurements on the battery. This approach communicates with the latter instead of discarding them.

The shared Arduino IDE screenshot has Teensy 4.1 selected and shows cell-voltage output for ICs numbered 1 through 18, with six channels per IC. Displayed values sit around 3.91 V. Another screenshot shows GPIO and reference-voltage readings; those are not themselves a display of calibrated temperatures.

Memory sets the controller choice

Lost-Bed-8458 also reports testing with an Arduino Uno R3 and Mega 2560 R3. In their implementation, the Uno’s memory limits communication to at most two battery modules, called “packs” in the post. For the nine-module arrangement intended for their conversion, they say a Mega or Teensy 4.1 is needed.

The Teensy choice also fits their broader openVCU plans. They cite its 600 MHz clock, price below $30, quick startup and low power consumption as reasons to make it a recurring part of that architecture. Those are the builder’s selection criteria, not vehicle-level performance results from this test.

The workshop photo puts the scale in perspective: multiple battery modules occupy the floor, while a laptop, meter, breadboards and interface electronics form the test setup beside them. This remains development hardware, not a finished vehicle installation.

From readings to a complete BMS

The planned openVCU BMS will draw on the Analog Devices Linduino library and the Ennoid-BMS open-source project, with KiCad used for PCB design. The builder points to openVCU for updates and says GitHub material will follow as testing progresses. They also report a cost below $35/kWh for their batteries; that figure should not be read as a budget for a finished, installed storage system.

Mechanical work is progressing alongside the electronics. In a follow-up, the creator describes scanning a module to design the conversion’s front battery enclosure. They consider the resulting STL rough but useful for locating mounting holes, and plan to share the fuller point-cloud and preprocessed scans too.

Other builders raised two worthwhile next questions: whether an existing LTC68XX-based BMS master could communicate with these boards, and how the software would be validated, including hardware-in-the-loop testing. Neither compatibility nor a completed validation program was demonstrated in the update.

Reading battery data and safely managing a battery are different milestones. The next useful evidence would show how the controller handles missing communications, implausible measurements and conditions requiring shutdown. For now, the project establishes a promising route to retaining Rivian’s monitoring boards—and gives the forthcoming BMS work a concrete interface to build around.

Editorial highlight by the Visual Space team.

Source: Update on Rivian Battery Packs

Sustainable Tech

1 Follower

Explore technology that uses resources more thoughtfully. Share projects and evidence around energy, repair, materials and circular design; compare practical tradeoffs and discuss what works, what lasts, and how environmental claims are measured.

Visual Space is built for projects like this—where creators collaborate, organize goals, and grow communities around real work.