A smart-home interface has a fairly unforgiving job: turning on a light should be easier than troubleshooting a connection. John Jensen’s Smart Home controllers project on Hackaday.io approached that problem with touchscreens in individual rooms and a master controller intended to coordinate the house. Created on May 20, 2015, the project reached a reported working single-room test bed before its software ambitions pushed it beyond the original ATmega328P hardware.
The interesting part is the gap between those two scales. A responsive room interface was taking shape; a complete, connected home-control system was still work in progress.
Put everyday controls in the room
Jensen’s initial design paired an Arduino Uno with an Adafruit 2.8-inch TFT touchscreen, choosing a format intended to fit a standard outlet box. Each room controller was meant to handle HVAC, lighting, intercom and stereo controls, alerts, and an alarm clock. Above those local interfaces, the proposed master would monitor rooms, override their settings, provide calendar-based timers, and serve as the system’s internet gateway. The component list included a BeagleBone Black alongside the Arduino and display.
Energy use was the larger motivation. Jensen wanted to monitor electricity and water consumption, adjust temperatures remotely, and eventually detect conditions such as an open window or a burst pipe. Those were project goals, not demonstrated whole-house capabilities in the visible logs.
The touchscreen work provides a more concrete view of what had been implemented. In the July 10 slider-control log, Jensen showed code for drawing a vertical slider from rectangles, tick marks, and numeric labels. The controls could be placed wherever the interface needed them. He described refreshing only the area affected by a moved button rather than redrawing everything—a useful way to keep a small display interface responsive.
There was also an early usability result: Jensen reported that his wife could dim a light with the slider even without a button marking her finger’s position. That’s a narrow test, but a meaningful one for a device whose everyday purpose was direct control.
The interface grows beyond the original processor
By July 26, Jensen reported that roughly 90 percent of the touch code was finished. He could create and destroy screen objects and detect touches on them. Tests and screen layouts were in place, but the code still needed consolidation and integration before he considered the room controller done.
The next major constraint was fitting the software onto the hardware. In the August 3 update, Jensen said he couldn’t fit everything onto the ATmega328P and had ordered an STM32F103 and ST-Link. He also described his individual-room test bed as fully working. Those statements mark different boundaries: a successful room-level test did not mean the complete intended system fit its original controller.
The processor change was a next step, not a finished upgrade. On August 17, the STM32F103C8 development environment was working and an LED blinked, while bringing up the LCD remained ahead. The latest supplied log, dated October 26, 2015, reported completed soldering and planned code changes, with Jensen hoping to get the screen running on ARM that week. It did not report that milestone as achieved.
Connecting rooms adds a different set of problems
The wider system was developing alongside the interface. A July 17 board-layout update described a configurable node board for motion, door/window, and water sensors, with possible relay use. Jensen was laying it out in KiCad, considering ESP8266 control and jumper-selected configurations; protection diodes still needed to be added. This was board-design work, not evidence of an installed sensing or protection system.
Software integration was similarly exploratory. In the July 12 LinuxMCE log, Jensen said he had begun working toward support in that system and planned a virtual machine for testing. The master-to-room communication protocol also appeared on the project’s to-do list.
A July 27, 2018 comment asked how the system had been secured. No answer is included in the visible discussion. That leaves an important open question for an architecture whose master was intended to bridge local controls to the internet; the working touchscreen tests don’t establish network security.
What this project makes especially clear is that interface usability, firmware fit, and whole-house integration are separate milestones. Jensen had tangible progress on the first, hit a limit on the second, and was still developing the third. The next convincing demonstration would have been the room interface running on the replacement processor, followed by a documented master-to-room connection—including what local controls do when that connection disappears.
Source: Smart Home controllers