Delta Flyer had a specific job in mind: turn CT and MRI data into physical models of body parts, ideally at or near full scale. DocDawning shared the enlarged Kossel Mini-style build on Hackaday.io, documenting both the machine and the practical work of getting it running. One of its most useful lessons came when replacing visibly imperfect rollers failed to improve the first prints.
The project was created on March 13, 2016, and the supplied logs run through March 14, 2017. This is a build history with a reported anatomy-printing result, not a newly launched printer.
Better rollers didn’t fix the first prints
Delta Flyer began with an inexpensive substitute for dedicated motion hardware: Prime Line shower-door rollers. In the March 13, 2016 entry, DocDawning reported finding them locally for about $1.80 each and treated them as a starting point rather than a permanent solution.
By the April 3 roller update, the tradeoff was clear. The rollers had play, but produced what DocDawning described as passable motion. Replacing them with Delrin rollers seemed an obvious improvement—until the first prints looked exactly the same.
The investigation then turned up a larger problem: the print bed could move during printing. DocDawning identified that as the main source of error. The roller swap hadn’t established how good the cheap wheels could be; another moving part had obscured the comparison.
That distinction matters. DocDawning suspected the inexpensive bearings would become troublesome at higher speeds, but didn’t establish a speed or quality limit. The evidence supports a narrower, more useful lesson: before judging an upgraded motion component, check that the surface receiving the print stays put.
A pen came before the hotend
The first calibration step deliberately left extrusion out of the picture. In the April 3 first-run log, DocDawning described assembling the moving parts, taking measurements and entering them into the Smoothieware configuration. Instead of installing the hotend immediately, the machine operated a Bic pen.
That gave the build a simpler initial task: demonstrate coordinated motion before attempting a three-dimensional print. It didn’t prove extrusion performance or accuracy throughout the build volume, but it separated the initial geometry setup from the complications of depositing plastic. DocDawning considered it a worthwhile precaution against measurement mistakes.
The machine used a Smoothieboard for control and OctoPrint through OctoPi over Wi-Fi. Its stated dimensions—1,000 mm vertical towers, 360 mm sides and a 250 mm build plate—describe a tall machine, not a guaranteed anatomical printing envelope. The project overview explicitly cautioned that a full-size skull or pelvis would probably be difficult.
The case became part of the machine
Portability brought another design problem. In the September 13, 2016 TARDIS-frame log, DocDawning explained that the exposed Kossel-style mechanism and unhoused electronics needed protection for transport.
The resulting case did several jobs: it protected the printer, provided a rigid structure to brace the tall towers, housed accessible electronics and made the assembly easier to stack among cargo. Rather than serving only as a cover, it became part of how the printer was supported and moved.
December updates addressed smaller integration details. The Illuminatrix lighting installation used an added vertical support for an LED bar, with an Arduino Mini connected to the Raspberry Pi and controlled through an OctoPrint plugin. A separate power-switch housing gave a previously loose rocker switch a dedicated enclosure.
The anatomy goal reached a reported print
On March 14, 2017, DocDawning reported deriving a skull model from raw CT data and printing multiple copies. That fulfilled one of the stated reasons for building Delta Flyer, though the excerpt gives no dimensions or accuracy measurements. It demonstrates a reported scan-to-print result, not validation for clinical use.
The project points to its GitHub repository for a detailed parts, sourcing and modification list. For another printer builder, though, the most transferable detail is the diagnostic sequence: simplify the first motion test, secure the bed, and only then assess what better rollers actually change. A more precise component can’t reveal its benefit while a larger error remains elsewhere in the machine.
Source: Delta Flyer